{"id":4650,"date":"2024-02-09T17:36:31","date_gmt":"2024-02-09T16:36:31","guid":{"rendered":"https:\/\/testritje.nl\/?p=4650"},"modified":"2024-10-30T12:24:21","modified_gmt":"2024-10-30T11:24:21","slug":"what-is-minimum-ignition-energy-mie","status":"publish","type":"post","link":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/","title":{"rendered":"What is Minimum Ignition Energy (MIE)?"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-right:0px;--awb-padding-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1248px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><p>Understanding the Minimum Ignition Energy, or MIE, is critical in industries where combustible dusts and vapours are present. For dusts this would include woodworking processes, or metalworking, particularly with polishing and grinding operations; agriculture, as well, since silo\u00a0<a href=\"https:\/\/cobic-ex.com\/what-is-an-explosion\/\">explosions<\/a>\u00a0can occur when storing grains; and food processing, especially when dealing with flours, sugars, and other extremely fine materials.<\/p>\n<p>Vapours propagate in many working environments, too. Painting operations involving car parts, for example, have an intrinsic danger. Many liquids are volatile but don\u2019t let that oft-confused word mislead you. Water is highly volatile, but since London still exists, we can all agree that fog (water vapour) is not flammable or explosive under most circumstances.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">What is MIE in a nutshell?<\/h2><\/div><div class=\"fusion-text fusion-text-2\"><p>Minimum Ignition Energy (MIE) is the\u00a0<strong>lowest energy required to ignite a mixture of a flammable substance with air<\/strong>, measured in millijoules (mJ).<\/p>\n<p>It varies with the type of substance and its concentration and is critical for assessing explosion risks in safety applications.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"1024\" height=\"548\" alt=\"Footprint in a thick layer of dust, this environment is not safe to work in.\" title=\"foot-print-in-dust\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp\" class=\"img-responsive wp-image-4679\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust-300x161.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust-500x268.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust-700x375.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust-768x411.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp 1024w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/span><\/div><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Industrial Processes Prone to Explosions<\/h2><\/div><div class=\"fusion-text fusion-text-3\"><p>The danger lies in combustible or flammable vapours, like VOCs (<a href=\"https:\/\/www.epa.gov\/indoor-air-quality-iaq\/technical-overview-volatile-organic-compounds#:~:text=Volatile%20organic%20compounds%20(VOC)%20means,having%20negligible%20photochemical%20reactivity2.\">Volatile Organic Chemicals<\/a>) which include hydrocarbons. This name may partially explain why some people confuse\u00a0<em>volatile<\/em>\u00a0with\u00a0<em>explosive<\/em>. VOCs also include alcohols, aldehydes, ketones, ethers, and aromatics like benzene, all of which are flammable.<\/p>\n<p>Consequently, danger exists in petroleum processing, oil and gas exploration, and doubly so in coal mining operations where both dust and flammable vapours (methane) coexist.<\/p>\n<p>Other dangerous areas include things you wouldn\u2019t suspect, like pill manufacturing where powders are highly compressed to make tablets\u2014indeed, even preparing the powders for that purpose. And don\u2019t forget rubber and plastic manufacturing, using powders in the process, and generating more in finishing operations.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"1024\" height=\"780\" alt=\"dust explosion \" title=\"dust-explosion\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/dust-explosion.webp\" class=\"img-responsive wp-image-4682\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/dust-explosion-300x229.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/dust-explosion-500x381.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/dust-explosion-700x533.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/dust-explosion-768x585.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/dust-explosion.webp 1024w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-4\"><p>Equally unexpected might be the textile industry where bolts of cloth are unwound and cut to size at high speed, launching fibres into the air, and creating static discharges in the process. The same applies to the paper and printing industry, and for precisely the same reasons.<\/p>\n<p>Combined industries, like recycling, can face all of these dangers at once when recycling metals, oils, fuels, paper, and plastics. This is why proper precautions and safety measures, including effective dust control, static discharge technology, and explosion prevention strategies, are essential to minimize the risk of dust or vapour related fires and explosions. Surprisingly the biggest risk is found\u00a0<em>inside<\/em>\u00a0the combustible dust collection systems due to overlooked maintenance!<\/p>\n<\/div><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">How Do We Measure MIE?<\/h2><\/div><div class=\"fusion-text fusion-text-5\"><p>Typically we measure MIE in a laboratory setting with gear designed for the purpose. The two most common methods involve either the Direct Spark method (sustained or static), and the Hot Surface method.<\/p>\n<p>In the first method, a test substance is evenly distributed in a chamber, and a low energy spark is introduced. In the case of dust, a mechanical system, like an air cannon will launch the material into a uniform cloud. Flammable vapours are much easier to work with obviously. The energy of the spark is increased until ignition is obtained and that value becomes the MIE, but only for that specific sample. Testing is usually done under STP (Standard Temperature and Pressure) conditions and then extrapolated for field conditions..<\/p>\n<p>The Hot Surface method uses a heated wire or coil and the temperature is raised until ignition is achieved. That is recorded as the MIE for that dust or gas.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-4 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Approriate units for measuring MIE<\/h3><\/div><div class=\"fusion-text fusion-text-6\"><p>MIE is typically measured in units of energy per unit mass, such as millijoules per gram (mJ\/g) or volumetrically as microjoules per cubic meter (\u00b5J\/m\u00b3). The lower the MIE value, the easier it is for the fuel to ignite. Anything possessing an MIE &lt;3\u00a0mJ is extremely sensitive to ignition and would demand very precise handling measures. By way of example, hydrogen in air at a 30% concentration would ignite at just 0.0057 mJ, or 5700 \u00b5J of energy.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-5 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">[Table] Mie of various substances<\/h3><\/div>\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Dust material<\/th>\n<th>MIE (mJ)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Aluminium<\/td>\n<td>&lt;1<\/td>\n<\/tr>\n<tr>\n<td>Bio-waste<\/td>\n<td>&gt;1000<\/td>\n<\/tr>\n<tr>\n<td>Coal<\/td>\n<td>&gt;1000 and 60<\/td>\n<\/tr>\n<tr>\n<td>Anthracite<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>Bituminous coal<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>Lignite<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>Charcoal<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>Magnesium<\/td>\n<td>&gt;1000 and 80<\/td>\n<\/tr>\n<tr>\n<td>Zinc<\/td>\n<td>300 and 9600<\/td>\n<\/tr>\n<tr>\n<td>Polystyrene<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>Urea<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>Calcium stearate<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Cornstarch<\/td>\n<td>10 and 30<\/td>\n<\/tr>\n<tr>\n<td>Corn flour<\/td>\n<td>20 and 40<\/td>\n<\/tr>\n<tr>\n<td>Pea flour<\/td>\n<td>40 and 100<\/td>\n<\/tr>\n<tr>\n<td>Sawdust<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Sugar<\/td>\n<td>10 and 30<\/td>\n<\/tr>\n<tr>\n<td>Sewage sludge<\/td>\n<td>100 and 8000<\/td>\n<\/tr>\n<tr>\n<td>Sulphur<\/td>\n<td>&lt;1<\/td>\n<\/tr>\n<tr>\n<td>Yeast<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>Wood<\/td>\n<td>40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"fusion-title title fusion-title-6 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">What Influences Its Explosivity?<\/h2><\/div><div class=\"fusion-text fusion-text-7\"><p>Particles bigger than 0.5 mm are resistant to ignition\u2014less than that size increases the ignition danger.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"562\" height=\"768\" alt=\"A graph showing the MIE ranges for gases (0.01-1 mJ) and dusts (1-1000+ mJ). In the third column we see practical examples of ignition sources. These are: Electrostatic discharges (1 mJ range); Sheaf of Grinding Sparks (10-100 mJ range) and Welding sparks (highest range)\" title=\"mie-values-and-ignition-sources\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/mie-values-and-ignition-sources.webp\" class=\"img-responsive wp-image-4685\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/mie-values-and-ignition-sources-220x300.webp 220w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/mie-values-and-ignition-sources-500x683.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/mie-values-and-ignition-sources.webp 562w\" sizes=\"(max-width: 1024px) 100vw, 562px\" \/><\/span><\/div><div class=\"fusion-title title fusion-title-7 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Combustible dust<\/h3><\/div><div class=\"fusion-text fusion-text-8\"><p>For combustible dusts, the MIE depends on various factors, including the particle size distribution, concentration in the air, and the specific properties of the dust itself. Finer dust particles have a higher surface area per unit mass, and are more prone to ignition. Additionally, the presence of certain gases in the environment can also influence the MIE. Even temperature can have a strong influence.<\/p>\n<p>For example, a small shallow dish of kerosene will extinguish a lit match at room temperature, but if the kerosene is heated to 45<strong>\u00e2\u201e\u0192<\/strong>\u00a0it will ignite because the vapour pressure is high enough for the match flame to supply the MIE. In this case, the &#8220;fuel&#8221; component of the fire triangle is missing until heat is applied to the kerosene.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-8 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Explosive gases and vapors<\/h3><\/div><div class=\"fusion-text fusion-text-9\"><p>This is also the explanation for why gas tanks never explode in cars (except in Hollywood Movies) because the fuel density is too high and there is insufficient oxygen available. As always, you can still get a fire, of course, when the fuel and vapour acquire sufficient oxygen from leaks or spillage. Interestingly, those stunt explosions are achieved with something called\u00a0<a href=\"https:\/\/en.wikipedia.org\/wiki\/Lycopodium_powder\">Lycopodium powder<\/a>\u00a0specifically because it is a very fine dust which ignites easily. It is launched into the air with an air-canon through a spark to make magnificent but short-lived fireballs that are extremely safe when handled by pyro-technicians.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-9 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Decreasing explosivity<\/h3><\/div><div class=\"fusion-text fusion-text-10\"><p>You can decrease explosivity by adding inerting substances such as sodium bicarbonate (used in fire extinguishers, since it is non-flammable and non-combustible). The relationship between v\/v% (volume per volume) or w\/w% (weight per weight) presence of inerting substances is not linear. Something with up to 80% inerting substance may still be significantly ignitable.<\/p>\n<p>MIE varies more closely with the inerting component, but is defined by the finest fraction of the combustible substance. If the particles become finer due to sieving and transfer operations during processing, the MIE can plummet presenting a hazard in (for example) pharmaceutical manufacturing.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img decoding=\"async\" width=\"1024\" height=\"1024\" alt=\"illustration of the hydrogen molecule\" title=\"h2 illustration\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration.webp\" class=\"img-responsive wp-image-4676\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-100x100.webp 100w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-140x140.webp 140w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-150x150.webp 150w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-200x200.webp 200w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-300x300.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-350x350.webp 350w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-500x500.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-700x700.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-768x768.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-800x800.webp 800w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration-1000x1000.webp 1000w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/h2-illustration.webp 1024w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/span><\/div><div class=\"fusion-title title fusion-title-10 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">The Takeaway<\/h2><\/div><div class=\"fusion-text fusion-text-11\"><p>Minimum Ignition Energy is\u00a0<em>not<\/em>\u00a0an intrinsic property of a substance or material. It is specific to the individual sample and its size distribution, usually based on the mean size, but the smallest particle size in the sample can significantly affect the MIE. Under\u00a0<a href=\"https:\/\/cobic-ex.com\/what-is-atex\/\">ATEX<\/a>, MIE plays a critical role in identifying hazards.<\/p>\n<p>It is also based on the morphology or shape of the particles, since irregular particles may present more surface area compared to volume, and decrease MIE. As an analogy, it would be much easier to ignite a slice of bacon than a cube of meat with the same mass since the surface area is comparatively huge. MIE varies, too, with moisture content which inhibits ignition, and higher humidity during processing can decrease the chances of sparks (electrostatic discharge).<\/p>\n<p>The atmospheric pressure can change how flame fronts propagate through a gas or dust cloud. Ambient temperature affects the MIE, as does the oxygen level. In fact, the Minimum Oxygen Concentration (MOC) is closely linked to the energy of the ignition source, with a direct correlation observed: higher oxygen concentrations reduce the requirement for ignition energy, while lower concentrations increase the need.<\/p>\n<p>In most cases, standardized testing procedures are available through organisations such as the American Society for Testing and Materials (<a href=\"https:\/\/www.astm.org\/\">ASTM<\/a>) or the International Electrotechnical Commission (IEC) to provide guidelines for testing MIE.<\/p>\n<p>MIE varies, even with the same material, depending on many external conditions. Extrapolating from laboratory testing results can be useful, but getting specific tests for your samples and conditions is far more revealing.<\/p>\n<\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":34,"featured_media":4677,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[38,40,116,117],"tags":[],"class_list":["post-4650","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-atex","category-explosion-protection","category-properties-of-gases-and-dusts","category-ignition-sources"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What is Minimum Ignition Energy (MIE)? - Cobic-Ex.com | Explosion Proof Equipment<\/title>\n<meta name=\"description\" content=\"Explore how factors like particle size, shape, moisture, and atmospheric conditions affect Minimum Ignition Energy (MIE).\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is Minimum Ignition Energy (MIE)?\" \/>\n<meta property=\"og:description\" content=\"Explore how factors like particle size, shape, moisture, and atmospheric conditions affect Minimum Ignition Energy (MIE).\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/\" \/>\n<meta property=\"og:site_name\" content=\"Cobic-Ex.com | Explosion Proof Equipment\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-09T16:36:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-30T11:24:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"548\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Gido van Tienhoven\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gido van Tienhoven\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/\"},\"author\":{\"name\":\"Gido van Tienhoven\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#\\\/schema\\\/person\\\/b168dc92fbe0ae84e5372077a9084b96\"},\"headline\":\"What is Minimum Ignition Energy (MIE)?\",\"datePublished\":\"2024-02-09T16:36:31+00:00\",\"dateModified\":\"2024-10-30T11:24:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/\"},\"wordCount\":6478,\"image\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/foot-print-in-dust.webp\",\"articleSection\":[\"ATEX Knowledge\",\"General Explosion Protection\",\"Properties of Gases and Dusts\",\"Ignition Sources\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/\",\"name\":\"What is Minimum Ignition Energy (MIE)? - Cobic-Ex.com | Explosion Proof Equipment\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/foot-print-in-dust.webp\",\"datePublished\":\"2024-02-09T16:36:31+00:00\",\"dateModified\":\"2024-10-30T11:24:21+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#\\\/schema\\\/person\\\/b168dc92fbe0ae84e5372077a9084b96\"},\"description\":\"Explore how factors like particle size, shape, moisture, and atmospheric conditions affect Minimum Ignition Energy (MIE).\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/foot-print-in-dust.webp\",\"contentUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/foot-print-in-dust.webp\",\"width\":1024,\"height\":548,\"caption\":\"Footprint in a thick layer of dust, this environment is not safe to work in.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-minimum-ignition-energy-mie\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/ecommerce-robust-landing\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is Minimum Ignition Energy (MIE)?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/\",\"name\":\"Cobic-Ex.com | Explosion Proof Equipment\",\"description\":\"ATEX, IECEx and NEC Certified Equipment.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#\\\/schema\\\/person\\\/b168dc92fbe0ae84e5372077a9084b96\",\"name\":\"Gido van Tienhoven\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/cropped-Gido-96x96.jpeg\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/cropped-Gido-96x96.jpeg\",\"contentUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/cropped-Gido-96x96.jpeg\",\"caption\":\"Gido van Tienhoven\"},\"description\":\"Gido van Tienhoven (MSc.) is the founder of Ex-Machinery and Armadex, specializing in ATEX explosion proof equipment. Educated at TU Delft, he is a prominent figure in the industry with expertise in explosion safety. His achievements include innovative products like explosion proof air conditioners and Wi-Fi solutions, and he is recognized for his significant contributions to safety in hazardous environments.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/gidovantienhoven\\\/\"],\"url\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/author\\\/gidovantienhoven\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"What is Minimum Ignition Energy (MIE)? - Cobic-Ex.com | Explosion Proof Equipment","description":"Explore how factors like particle size, shape, moisture, and atmospheric conditions affect Minimum Ignition Energy (MIE).","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/","og_locale":"it_IT","og_type":"article","og_title":"What is Minimum Ignition Energy (MIE)?","og_description":"Explore how factors like particle size, shape, moisture, and atmospheric conditions affect Minimum Ignition Energy (MIE).","og_url":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/","og_site_name":"Cobic-Ex.com | Explosion Proof Equipment","article_published_time":"2024-02-09T16:36:31+00:00","article_modified_time":"2024-10-30T11:24:21+00:00","og_image":[{"width":1024,"height":548,"url":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp","type":"image\/webp"}],"author":"Gido van Tienhoven","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Gido van Tienhoven","Tempo di lettura stimato":"7 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/#article","isPartOf":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/"},"author":{"name":"Gido van Tienhoven","@id":"https:\/\/cobic-ex.com\/it\/#\/schema\/person\/b168dc92fbe0ae84e5372077a9084b96"},"headline":"What is Minimum Ignition Energy (MIE)?","datePublished":"2024-02-09T16:36:31+00:00","dateModified":"2024-10-30T11:24:21+00:00","mainEntityOfPage":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/"},"wordCount":6478,"image":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/#primaryimage"},"thumbnailUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp","articleSection":["ATEX Knowledge","General Explosion Protection","Properties of Gases and Dusts","Ignition Sources"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/","url":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/","name":"What is Minimum Ignition Energy (MIE)? - Cobic-Ex.com | Explosion Proof Equipment","isPartOf":{"@id":"https:\/\/cobic-ex.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/#primaryimage"},"image":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/#primaryimage"},"thumbnailUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp","datePublished":"2024-02-09T16:36:31+00:00","dateModified":"2024-10-30T11:24:21+00:00","author":{"@id":"https:\/\/cobic-ex.com\/it\/#\/schema\/person\/b168dc92fbe0ae84e5372077a9084b96"},"description":"Explore how factors like particle size, shape, moisture, and atmospheric conditions affect Minimum Ignition Energy (MIE).","breadcrumb":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/#primaryimage","url":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp","contentUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/02\/foot-print-in-dust.webp","width":1024,"height":548,"caption":"Footprint in a thick layer of dust, this environment is not safe to work in."},{"@type":"BreadcrumbList","@id":"https:\/\/cobic-ex.com\/it\/what-is-minimum-ignition-energy-mie\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cobic-ex.com\/it\/ecommerce-robust-landing\/"},{"@type":"ListItem","position":2,"name":"What is Minimum Ignition Energy (MIE)?"}]},{"@type":"WebSite","@id":"https:\/\/cobic-ex.com\/it\/#website","url":"https:\/\/cobic-ex.com\/it\/","name":"Cobic-Ex.com | Explosion Proof Equipment","description":"ATEX, IECEx and NEC Certified Equipment.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cobic-ex.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/cobic-ex.com\/it\/#\/schema\/person\/b168dc92fbe0ae84e5372077a9084b96","name":"Gido van Tienhoven","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/04\/cropped-Gido-96x96.jpeg","url":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/04\/cropped-Gido-96x96.jpeg","contentUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/04\/cropped-Gido-96x96.jpeg","caption":"Gido van Tienhoven"},"description":"Gido van Tienhoven (MSc.) is the founder of Ex-Machinery and Armadex, specializing in ATEX explosion proof equipment. Educated at TU Delft, he is a prominent figure in the industry with expertise in explosion safety. His achievements include innovative products like explosion proof air conditioners and Wi-Fi solutions, and he is recognized for his significant contributions to safety in hazardous environments.","sameAs":["https:\/\/www.linkedin.com\/in\/gidovantienhoven\/"],"url":"https:\/\/cobic-ex.com\/it\/author\/gidovantienhoven\/"}]}},"_links":{"self":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/posts\/4650","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/comments?post=4650"}],"version-history":[{"count":0,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/posts\/4650\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/media\/4677"}],"wp:attachment":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/media?parent=4650"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/categories?post=4650"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/tags?post=4650"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}