{"id":4496,"date":"2024-01-26T09:39:56","date_gmt":"2024-01-26T08:39:56","guid":{"rendered":"https:\/\/testritje.nl\/?p=4496"},"modified":"2024-10-30T12:32:53","modified_gmt":"2024-10-30T11:32:53","slug":"what-is-en-1127-1","status":"publish","type":"post","link":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/","title":{"rendered":"What is EN 1127-1? European Standard Explained"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-right:0px;--awb-padding-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1248px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><p>EN 1127-1 is a European Standard that provides requirements and guidelines for the\u00a0<strong>prevention of explosions<\/strong>, as well as the\u00a0<strong>protection against explosions<\/strong>. It is written and maintained by the\u00a0<a href=\"https:\/\/www.cencenelec.eu\/\">European Committee for Standardization<\/a>\u00a0(CEN)<\/p>\n<p>According to the official document, the standard specifies basic methods and requirements which aim to ensure the s<strong>afety of workers<\/strong>\u00a0and the protection of the general public by\u00a0<strong>preventing the formation of explosive atmospheres<\/strong>\u00a0and\u00a0<strong>limiting the effects of explosions to an acceptable level<\/strong>.<\/p>\n<p>It covers the basic concepts and methodology for\u00a0<strong>design, operation, and maintenance of equipmen<\/strong>t, as well as the\u00a0<strong>safe handling of substances<\/strong>\u00a0in order to prevent\u00a0<a href=\"https:\/\/cobic-ex.com\/what-is-an-explosive-atmosphere\/\">explosive atmospheres<\/a>\u00a0and to protect against the hazards from such atmospheres.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"1792\" height=\"1024\" alt=\"Illustrative banner image, workers hat and stack of papers for European standard.\" title=\"en-1127-1 banner image\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image-.webp\" class=\"img-responsive wp-image-4495\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image--300x171.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image--500x286.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image--700x400.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image--768x439.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image--1024x585.webp 1024w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image--1536x878.webp 1536w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/en-1127-1-banner-image-.webp 1792w\" sizes=\"(max-width: 1024px) 100vw, 1792px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-2\"><p>This article offers a concise guide to the European Standard, highlighting the key points covered. Additionally, we touch on Section 5, which systematically outlines the thirteen identified ignition sources.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">A Comprehensive Overview of The Standard<\/h2><\/div><div class=\"fusion-text fusion-text-3\"><p>EN 1127-1:2011 comprehensively covers various aspects of explosion prevention and protection. The document is structured into several sections and clauses, each dealing with specific topics on to explosion risks and prevention methods.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"1024\" height=\"1024\" alt=\"Illustrative image of EN 1127-1 group training.\" title=\"Explanation to groups\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups.webp\" class=\"img-responsive wp-image-4489\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-100x100.webp 100w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-140x140.webp 140w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-150x150.webp 150w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-200x200.webp 200w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-300x300.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-350x350.webp 350w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-500x500.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-700x700.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-768x768.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-800x800.webp 800w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups-1000x1000.webp 1000w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Explanation-to-groups.webp 1024w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-4\"><p>First, the document initiates with the foreword, introduction, and normative references. It then progresses to encompass sections 3\u20137, providing descriptions of the following:<\/p>\n<\/div><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Terms and Definitions (Section 3)<\/h3><\/div><div class=\"fusion-text fusion-text-5\"><p>After covering the basics, this section provides definitions of key terms used throughout the standard.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Risk Assessment (Section 4)<\/h3><\/div><div class=\"fusion-text fusion-text-6\"><p>This crucial section discusses the general framework for risk assessment, including the identification of explosion hazards, ignition hazards, and the estimation of possible effects of an explosion. It also evaluates the risk and whether the intended level of protection has been achieved, and considerations for reducing risks.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"1168\" height=\"715\" alt=\"Example of an explosive atmosphere, gas piping in industrial site.\" title=\"hazardous-area\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/hazardous-area.webp\" class=\"img-responsive wp-image-4500\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/hazardous-area-300x184.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/hazardous-area-500x306.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/hazardous-area-700x429.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/hazardous-area-768x470.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/hazardous-area-1024x627.webp 1024w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/hazardous-area.webp 1168w\" sizes=\"(max-width: 1024px) 100vw, 1168px\" \/><\/span><\/div><div class=\"fusion-title title fusion-title-4 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Possible Ignition Sources (Section 5)<\/h3><\/div><div class=\"fusion-text fusion-text-7\"><p>This section details various potential sources of ignition, such as hot surfaces, flames and hot gases, mechanically generated sparks, electrical apparatus, stray electric currents, static electricity, lightning, radio frequency electromagnetic waves, ionizing radiation, ultrasonics, adiabatic compression and shock waves, and exothermic reactions including self-ignition of dusts.<\/p>\n<p>Examples of electrical apparatus commonly used in hazardous areas are:<\/p>\n<ul>\n<li>Tablets, phones, and cameras<\/li>\n<li>Measuring equipment<\/li>\n<li>Sensors and IOT Devices<\/li>\n<li>Wireless connectivity systems<\/li>\n<\/ul>\n<p>Standard consumer products are not allowed for use in hazardous areas, as they can generate heat (hot surface) and sparks (in the case of malfunction) and static electricity.<\/p>\n<p>Consequently, hazardous area designers often employ the protection method\u00a0<a href=\"https:\/\/cobic-ex.com\/intrinsically-safe-definition-explained\/\">intrinsic safety<\/a>\u00a0to ensure that electrical apparatus comply with explosion safety regulations.<\/p>\n<\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img decoding=\"async\" width=\"993\" height=\"342\" alt=\"Open flames are one of the most obvious and dangerous ignition sources.\" title=\"Open-flames-1\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Open-flames-1.webp\" class=\"img-responsive wp-image-4477\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Open-flames-1-300x103.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Open-flames-1-500x172.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Open-flames-1-700x241.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Open-flames-1-768x265.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Open-flames-1.webp 993w\" sizes=\"(max-width: 1024px) 100vw, 993px\" \/><\/span><\/div><div class=\"fusion-title title fusion-title-5 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Risk Reduction (Section 6)<\/h3><\/div><div class=\"fusion-text fusion-text-8\"><p>Here, fundamental principles for risk reduction are discussed, including the avoidance or reduction of the size of the explosive atmosphere, design and construction of equipment protective systems and components to avoid effective ignition sources, and principles of measuring and control systems for explosion prevention and protection.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-6 fusion-sep-none fusion-title-text fusion-title-size-three\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Information for Use (Section 7)<\/h3><\/div><div class=\"fusion-text fusion-text-9\"><p>This section provides guidelines for the information necessary for commissioning, maintenance, and repair to prevent explosions, including qualifications and training.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-7 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">All 13 Official Potential Ignition Sources<\/h2><\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-5 hover-type-none\"><img decoding=\"async\" width=\"1024\" height=\"416\" alt=\"Static electricity is a common ignition source, often caused by rubbing between various materials. \" title=\"static electricity (1)\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/static-electricity-1.webp\" class=\"img-responsive wp-image-4492\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/static-electricity-1-300x122.webp 300w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/static-electricity-1-500x203.webp 500w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/static-electricity-1-700x284.webp 700w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/static-electricity-1-768x312.webp 768w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/static-electricity-1.webp 1024w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-10\"><p>According to the European Standard EN 1127-1:2011 Section 5, there are 13 potential ignition sources in environments with explosive atmospheres. These sources are listed in the table below, including examples.<\/p>\n<\/div>\n<table width=\"100%\">\n<thead>\n<tr>\n<th><strong>Ignition Source<\/strong><\/th>\n<th><strong>Description and Examples<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Hot Surfaces<\/td>\n<td>Heated surfaces can ignite explosive atmospheres.<\/p>\n<p>This includes not only the surface itself but also any dust layer or combustible solid in contact with it.<\/p>\n<p>The ignition risk depends on the temperature, surface area, and the type of substance in the mixture with air.<\/td>\n<\/tr>\n<tr>\n<td>Flames and Hot Gases (Including Hot Particles)<\/td>\n<td>Flames, hot gases, and hot particles produced during combustion reactions can ignite explosive atmospheres.<\/p>\n<p>Even very small flames are effective sources of ignition.<\/td>\n<\/tr>\n<tr>\n<td>Mechanically Generated Sparks<\/td>\n<td>Sparks generated from friction, impact, or abrasion processes, like grinding, can ignite combustible gases, vapors, and certain dust\/air mixtures.<\/p>\n<p>Oxidizable substances like iron or steel can reach high temperatures and ignite explosive atmospheres.<\/td>\n<\/tr>\n<tr>\n<td>Electrical Apparatus<\/td>\n<td>Electric sparks and hot surfaces from\u00a0<a href=\"https:\/\/dictionary.cambridge.org\/example\/english\/electrical-apparatus\">electrical apparatus<\/a>\u00a0can be ignition sources.<\/p>\n<p>These sparks can occur when electric circuits are opened and closed, due to loose connections, or from stray currents.<\/td>\n<\/tr>\n<tr>\n<td>Stray Electric Currents and Cathodic Corrosion Protection<\/td>\n<td>Stray currents can flow in conductive systems or parts, leading to sparks and potential ignition.<\/p>\n<p>These currents can result from various scenarios, including faults in electrical installations and magnetic induction.<\/td>\n<\/tr>\n<tr>\n<td>Static Electricity<\/td>\n<td>Discharges of static electricity can lead to incendive sparks.<\/p>\n<p>This includes brush discharges, cone discharges, and cloud discharges from charged, insulated conductive parts and non-conductive materials.<\/td>\n<\/tr>\n<tr>\n<td>Lightning<\/td>\n<td>Lightning strikes in an explosive atmosphere will always cause ignition.<\/p>\n<p>The high temperature reached by lightning conductors and large currents produced near the point of impact can also be ignition sources.<\/td>\n<\/tr>\n<tr>\n<td>Radio Frequency (RF) Electromagnetic Waves<\/td>\n<td>Electromagnetic waves emitted by radio-frequency systems can cause ignition in explosive atmospheres if conductive parts in the radiation field absorb sufficient energy.<\/td>\n<\/tr>\n<tr>\n<td>Electromagnetic Waves (Higher Frequencies)<\/td>\n<td>Radiation in higher frequency ranges, including sunlight and laser radiation, can become ignition sources through absorption by explosive atmospheres or solid surfaces.<\/td>\n<\/tr>\n<tr>\n<td>Ionizing Radiation<\/td>\n<td>Ionizing radiation from sources like X-ray tubes and radioactive substances can ignite explosive atmospheres, especially those with dust particles.<\/p>\n<p>This can result from energy absorption or heating up of the radioactive source.<\/td>\n<\/tr>\n<tr>\n<td>Ultrasonics<\/td>\n<td><a href=\"https:\/\/en.wikipedia.org\/wiki\/Ultrasound\">Ultrasonic sound waves<\/a>\u00a0can heat substances to temperatures that may induce ignition.<\/td>\n<\/tr>\n<tr>\n<td>Adiabatic Compression and Shock Waves<\/td>\n<td>High temperatures resulting from adiabatic or nearly adiabatic compression and shock waves can ignite explosive atmospheres and dust layers.<\/td>\n<\/tr>\n<tr>\n<td>Exothermic Reactions Including Self-Ignition of Dusts<\/td>\n<td>Exothermic chemical reactions can lead to high temperatures that ignite explosive atmospheres.<\/p>\n<p>This includes the self-ignition of dusts and the initiation of smouldering or burning.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-6 hover-type-none\"><img decoding=\"async\" width=\"600\" height=\"600\" alt=\"This GETAC Explosion Proof Tablet is ATEX and IECEx certified for zones 2 and 22. \" title=\"UX10-EX FAF\" src=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/01\/UX10-EX-FAF.jpg\" class=\"img-responsive wp-image-3122\" srcset=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/01\/UX10-EX-FAF-200x200.jpg 200w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/01\/UX10-EX-FAF-400x400.jpg 400w, https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/01\/UX10-EX-FAF.jpg 600w\" sizes=\"(max-width: 1024px) 100vw, 600px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-11\"><p>The electrical apparatus displayed above is an ATEX tablet, certified for ATEX (and IECEx) zones 2 and 22, making it\u00a0<a href=\"https:\/\/oshwiki.osha.europa.eu\/en\/themes\/safety\">safe<\/a>\u00a0to use in explosive atmospheres classified accordingly.<\/p>\n<p>This certification essentially means that the tablet is very unlikely to form a source of ignition, and its risk level is deemed acceptable according to ATEX and IECEx standards.<\/p>\n<\/div><div class=\"fusion-title title fusion-title-8 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">The Takeaway<\/h2><\/div><div class=\"fusion-text fusion-text-12\"><p>In this article, we aimed to provide you with a foundational understanding of the content encapsulated in EN 1127-1. The complete document spans approximately 50 pages and is available for purchase through various online vendors. For further insights and information, we encourage you to explore our blogs and articles on explosion safety at <a href=\"https:\/\/cobic-ex.com\/blog\/\">https:\/\/cobic-ex.com\/blog\/<\/a>.<\/p>\n<\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":34,"featured_media":4482,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[38,114,117],"tags":[],"class_list":["post-4496","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-atex","category-atex-legislation","category-ignition-sources"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What is EN 1127-1? European Standard Explained - Cobic-Ex.com | Explosion Proof Equipment<\/title>\n<meta name=\"description\" content=\"This article summarizes the contents of European Standard EN 1127-1 and specifically looks at section 6, describing all 13 ignition sources.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is EN 1127-1? European Standard Explained\" \/>\n<meta property=\"og:description\" content=\"This article summarizes the contents of European Standard EN 1127-1 and specifically looks at section 6, describing all 13 ignition sources.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Cobic-Ex.com | Explosion Proof Equipment\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-26T08:39:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-30T11:32:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Paperwork.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1792\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Gido van Tienhoven\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gido van Tienhoven\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/\"},\"author\":{\"name\":\"Gido van Tienhoven\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#\\\/schema\\\/person\\\/b168dc92fbe0ae84e5372077a9084b96\"},\"headline\":\"What is EN 1127-1? European Standard Explained\",\"datePublished\":\"2024-01-26T08:39:56+00:00\",\"dateModified\":\"2024-10-30T11:32:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/\"},\"wordCount\":6437,\"image\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Paperwork.webp\",\"articleSection\":[\"ATEX Knowledge\",\"ATEX Legislation\",\"Ignition Sources\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/\",\"name\":\"What is EN 1127-1? European Standard Explained - Cobic-Ex.com | Explosion Proof Equipment\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Paperwork.webp\",\"datePublished\":\"2024-01-26T08:39:56+00:00\",\"dateModified\":\"2024-10-30T11:32:53+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#\\\/schema\\\/person\\\/b168dc92fbe0ae84e5372077a9084b96\"},\"description\":\"This article summarizes the contents of European Standard EN 1127-1 and specifically looks at section 6, describing all 13 ignition sources.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Paperwork.webp\",\"contentUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Paperwork.webp\",\"width\":1792,\"height\":1024,\"caption\":\"Illustrative stack of paperwork\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/what-is-en-1127-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/ecommerce-robust-landing\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is EN 1127-1? European Standard Explained\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/\",\"name\":\"Cobic-Ex.com | Explosion Proof Equipment\",\"description\":\"ATEX, IECEx and NEC Certified Equipment.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/#\\\/schema\\\/person\\\/b168dc92fbe0ae84e5372077a9084b96\",\"name\":\"Gido van Tienhoven\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/cropped-Gido-96x96.jpeg\",\"url\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/cropped-Gido-96x96.jpeg\",\"contentUrl\":\"https:\\\/\\\/cobic-ex.com\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/cropped-Gido-96x96.jpeg\",\"caption\":\"Gido van Tienhoven\"},\"description\":\"Gido van Tienhoven (MSc.) is the founder of Ex-Machinery and Armadex, specializing in ATEX explosion proof equipment. Educated at TU Delft, he is a prominent figure in the industry with expertise in explosion safety. His achievements include innovative products like explosion proof air conditioners and Wi-Fi solutions, and he is recognized for his significant contributions to safety in hazardous environments.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/gidovantienhoven\\\/\"],\"url\":\"https:\\\/\\\/cobic-ex.com\\\/it\\\/author\\\/gidovantienhoven\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"What is EN 1127-1? European Standard Explained - Cobic-Ex.com | Explosion Proof Equipment","description":"This article summarizes the contents of European Standard EN 1127-1 and specifically looks at section 6, describing all 13 ignition sources.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/","og_locale":"it_IT","og_type":"article","og_title":"What is EN 1127-1? European Standard Explained","og_description":"This article summarizes the contents of European Standard EN 1127-1 and specifically looks at section 6, describing all 13 ignition sources.","og_url":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/","og_site_name":"Cobic-Ex.com | Explosion Proof Equipment","article_published_time":"2024-01-26T08:39:56+00:00","article_modified_time":"2024-10-30T11:32:53+00:00","og_image":[{"width":1792,"height":1024,"url":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Paperwork.webp","type":"image\/webp"}],"author":"Gido van Tienhoven","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Gido van Tienhoven","Tempo di lettura stimato":"6 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/#article","isPartOf":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/"},"author":{"name":"Gido van Tienhoven","@id":"https:\/\/cobic-ex.com\/it\/#\/schema\/person\/b168dc92fbe0ae84e5372077a9084b96"},"headline":"What is EN 1127-1? European Standard Explained","datePublished":"2024-01-26T08:39:56+00:00","dateModified":"2024-10-30T11:32:53+00:00","mainEntityOfPage":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/"},"wordCount":6437,"image":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/#primaryimage"},"thumbnailUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Paperwork.webp","articleSection":["ATEX Knowledge","ATEX Legislation","Ignition Sources"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/","url":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/","name":"What is EN 1127-1? European Standard Explained - Cobic-Ex.com | Explosion Proof Equipment","isPartOf":{"@id":"https:\/\/cobic-ex.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/#primaryimage"},"image":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/#primaryimage"},"thumbnailUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Paperwork.webp","datePublished":"2024-01-26T08:39:56+00:00","dateModified":"2024-10-30T11:32:53+00:00","author":{"@id":"https:\/\/cobic-ex.com\/it\/#\/schema\/person\/b168dc92fbe0ae84e5372077a9084b96"},"description":"This article summarizes the contents of European Standard EN 1127-1 and specifically looks at section 6, describing all 13 ignition sources.","breadcrumb":{"@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/#primaryimage","url":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Paperwork.webp","contentUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2024\/01\/Paperwork.webp","width":1792,"height":1024,"caption":"Illustrative stack of paperwork"},{"@type":"BreadcrumbList","@id":"https:\/\/cobic-ex.com\/it\/what-is-en-1127-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cobic-ex.com\/it\/ecommerce-robust-landing\/"},{"@type":"ListItem","position":2,"name":"What is EN 1127-1? European Standard Explained"}]},{"@type":"WebSite","@id":"https:\/\/cobic-ex.com\/it\/#website","url":"https:\/\/cobic-ex.com\/it\/","name":"Cobic-Ex.com | Explosion Proof Equipment","description":"ATEX, IECEx and NEC Certified Equipment.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cobic-ex.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/cobic-ex.com\/it\/#\/schema\/person\/b168dc92fbe0ae84e5372077a9084b96","name":"Gido van Tienhoven","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/04\/cropped-Gido-96x96.jpeg","url":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/04\/cropped-Gido-96x96.jpeg","contentUrl":"https:\/\/cobic-ex.com\/wp-content\/uploads\/2023\/04\/cropped-Gido-96x96.jpeg","caption":"Gido van Tienhoven"},"description":"Gido van Tienhoven (MSc.) is the founder of Ex-Machinery and Armadex, specializing in ATEX explosion proof equipment. Educated at TU Delft, he is a prominent figure in the industry with expertise in explosion safety. His achievements include innovative products like explosion proof air conditioners and Wi-Fi solutions, and he is recognized for his significant contributions to safety in hazardous environments.","sameAs":["https:\/\/www.linkedin.com\/in\/gidovantienhoven\/"],"url":"https:\/\/cobic-ex.com\/it\/author\/gidovantienhoven\/"}]}},"_links":{"self":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/posts\/4496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/comments?post=4496"}],"version-history":[{"count":0,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/posts\/4496\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/media\/4482"}],"wp:attachment":[{"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/media?parent=4496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/categories?post=4496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cobic-ex.com\/it\/wp-json\/wp\/v2\/tags?post=4496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}