Armadex Ex UniCase Galaxy Tab S10 FE

€1,700.00

Armadex

Type: Ex UniCase Galaxy Tab S10 FE

Ex-marking II 3G Ex nR IIC T6 Gc | II 3D Ex tc IIIC T85°C Dc
Certification ATEX & IECEx Zone 2/22
Ambient temperature -20 °C to +50 °C (operating) · storage up to +60 °C
Ingress protection IP64
Materials ESD-safe POM-C · Gorilla Glass window · polycarbonate back cover
Installation Outside the hazardous area · approx. 15 min · Armadex-approved tablets only
Compatibility Samsung Galaxy Tab S10 FE (10.9″) · tablet not included
Availability Lead time on request

Description

Armadex Ex UniCase Galaxy Tab S10 FE · ATEX & IECEx Zone 2/22

The Armadex Ex UniCase Galaxy Tab S10 FE is a certified enclosure that makes the Samsung Galaxy Tab S10 FE (10.9″) suitable for hazardous areas in Zone 2 and Zone 22 (II 3G Ex nR IIC T6 Gc, II 3D Ex tc IIIC T85°C Dc). The enclosure is supplied without tablet. Device-specific inlays position the tablet and three stainless steel push buttons operate its buttons, while cameras, microphone, speakers and the USB-C port remain accessible. The tablet is installed outside the hazardous area and can later be replaced or upgraded while the certified enclosure is retained. IP64, ambient temperature -20 °C to +50 °C.

Why the Ex UniCase Galaxy Tab S10 FE?

  • ATEX and IECEx Zone 2/22: II 3G Ex nR IIC T6 Gc · II 3D Ex tc IIIC T85°C Dc
  • Fits the Samsung Galaxy Tab S10 FE (10.9″); tablet not included
  • Full access to buttons, cameras, microphone, speakers and USB-C via 3 stainless steel push buttons
  • ESD-safe POM-C enclosure, Gorilla Glass display window, polycarbonate back cover, IP64
  • Tablet replaceable via device-specific inlays without re-certifying the enclosure (Armadex-approved tablets)

Suitable for

Zone 2/22 areas in chemical and petrochemical plants, oil & gas, pharma and logistics: operator rounds, permit-to-work, communication, scanning, documentation and remote assistance.

Globally certified

ATEX and IECEx Zone 2/22 (II 3G Ex nR IIC T6 Gc | II 3D Ex tc IIIC T85°C Dc) plus further country certifications where applicable.

Additional information

Brand

Ex Markings

ATEX: II 3G Ex nR IIC T6 Gc · II 3D Ex tc IIIC T85°C Dc
IECEx: Ex nR IIC T6 Gc · Ex tc IIIC T85°C Dc
Ta: -20 °C to +50 °C

Certificates

ATEX: OBAC 26ATEX0194X
IECEx: IECEx OBAC 26.0005X
(issued for the Armadex Ex UniCase Small, Medium or Large enclosure)

Standards

EN IEC 60079-0:2018, EN IEC 60079-15:2019, EN IEC 60079-31:2024
IEC 60079-0:2017, IEC 60079-15:2017, IEC 60079-31:2022

Compatible device

Samsung Galaxy Tab S10 FE (10.9"), not included

Features

Full access to buttons, cameras, microphone, speakers and USB-C port
3 stainless steel push buttons operate the tablet buttons via a patented inlay system
Wireless data transmission via WiFi and Bluetooth
Integrated test port for the Ex nR restricted breathing test
Tablet replaceable or upgradeable via device-specific inlays; the certified enclosure is retained

Materials

Enclosure: ESD-safe POM-C
Display window: impact-resistant Gorilla Glass
Back cover: hard-coated, anti-static polycarbonate
Seal: 3 mm silicone rubber O-ring
Inlays: device-specific, modular ABS corner inlays

Degree of protection

IP64

Special conditions

Open or close the Ex UniCase only outside the hazardous area
USB lid and test port plug must always be fitted in the hazardous area
USB port for use in non-hazardous areas only (charge outside the hazardous area)
Protect against high impact energy, excessive UV light and high electrostatic charging processes

Installation

Tablet installation outside the hazardous area only, approx. 15 minutes, no specialist tools
Only tablets approved (whitelisted) by Armadex; an unapproved device voids the ATEX/IECEx conformity
Per the IECEx certificate, a routine test (IEC 60079-15, 10.3) is required for each new tablet type not previously tested

Scope of delivery

Ex UniCase enclosure with USB-C lid fitted
Transparent polycarbonate backplate
4 inlays (button inlay plus inlays 1, 2 and 3)
3 stainless steel push buttons and 1 test port plug
20 × M3 countersunk screws (A2 stainless steel), 2 hex keys
Test port connector hose
Bezel (Samsung)
Tablet not included

Geographic Certification

,

Zone Classification

,

PDF Datasheet Viewer

Geographic suitability

Check the top-left corner of the product image for certifications. For the latest details, refer to the datasheet or contact us. Generally, these certifications apply to the following regions: 

Certification Geography
NEC/CEC (Class/Division) USA, Canada
NEC/CEC (Class/Zone) USA, Canada
ATEX Mandatory in EU, EEA, Turkey and United Kingdom.
Accepted in most countries not listed elsewhere in this table.
INMETRO Brazil (based on IECEx)
IECEx Mandatory in Australia and Israel.
Accepted in most countries not listed elsewhere in this table.

Check our comprehensive guide on explosion proof equipment certifications and where they're recognized.

Downloads

Datasheet

Brochure

ATEX Certificate

IECEx Certificate

Quick Start Guide